Finding a Cable Fault with NanoVNA: Distance to Fault (TDR)
You cannot cut a cable under the roof or in a conduit in half to see where it is damaged. But any damage reflects part of the signal, and the reflection comes back with a delay proportional to the distance. A NanoVNA can measure that delay — a fifty-dollar instrument many people already have in the shack. Below are two ways to do it, what limits range and accuracy, and how to read the picture.
The distance-to-fault calculator works out the distance from the measured numbers.
What reflects
A 50-ohm cable terminated in 50 ohms reflects nothing: the wave travels to the end and is absorbed there. Any place where the characteristic impedance differs reflects part of the wave back:
| What is in the cable | Impedance there | Reflection |
|---|---|---|
| open circuit | infinite | total, same sign |
| short circuit | zero | total, opposite sign |
| water under the jacket | lower: water adds capacitance | weak and smeared along the length |
| crushed cable | lower: conductors closer together | weak, at one point |
| bad connector, adapter | different for a few centimetres | a short blip |
The distance to the reflection:
d = c · vf · t / 2
t is the delay and vf the cable's velocity factor. We divide by two because the signal covers the distance twice, there and back.
Velocity factor first
Both methods below give a time or a frequency; the distance only comes through vf. An error in vf is the same error in the distance: vf 0.66 instead of 0.82 puts the fault a fifth closer than it really is. Tables give vf by insulation type: solid polyethylene about 0.66, foam 0.78–0.85, PTFE about 0.7. But the same type of cable from different factories can differ.
It is more reliable to measure vf on a piece of the same reel of known length. Leave the far end open, find the first frequency at which the impedance drops to a minimum (a quarter wave fits in the cable there), and work out:
vf = 4 · L · f₁ / c
For 5 m of cable with vf 0.66 the first minimum is at about 9.9 MHz. The velocity factor calculator does the same.
Method one: resonance spacing
This works on any analyser, even without a TDR mode. Disconnect the antenna, leave the far end of the cable open and sweep S11 or impedance over a wide band. The impedance minima repeat at a constant spacing Δf, and that spacing gives the length to the point where the cable electrically ends — an open, a short or the real end:
d = c · vf / (2 · Δf)
20 m of RG-58 (vf 0.66) gives a spacing of 4.95 MHz. If the spacing came out at 9.9 MHz, the fault is 10 m away. The more minima in the band, the better: measure from the first to the tenth and divide by nine.
This method only sees the strongest reflection. Water or a bad connector halfway along adds a faint ripple on top of the main minima, but you cannot get a distance to it this way.
Method two: TDR
The analyser measures S11 at hundreds of frequencies, and maths turns those measurements into a response in time: what would come back if a short pulse or a step were sent into the cable. That is TDR (time domain reflectometry). NanoVNA-Saver has a separate window for it, where you enter the velocity factor and get the impedance along the cable. The NanoVNA itself has a time-domain transform mode (TRANSFORM), with a velocity factor setting too.
There are two modes:
- impulse — sharp peaks wherever something reflects; handy for finding the place;
- step — an impedance profile along the cable; it shows what it is: an open goes up, a short down, water as a gentle dip.
Range and resolution
Both depend on how you set up the sweep:
range d_max = c · vf / (2 · frequency step)
resolution Δd ≈ c · vf / (2 · span)
The frequency step is the span divided by the number of points minus one. For cable with vf 0.66:
| Sweep | Range | Resolution |
|---|---|---|
| 101 points, up to 900 MHz | 11 m | 11 cm |
| 101 points, up to 330 MHz | 30 m | 30 cm |
| 1001 points, up to 900 MHz | 110 m | 11 cm |
Range is set by the number of points, resolution by the span. So a long feedline needs a sweep with many points; NanoVNA-Saver can assemble one from several passes. The window that smooths the transform widens every peak roughly twofold, so real resolution is worse than the table.
If a fault lies beyond the range, it does not disappear: it is carried over to a wrong, shorter distance. The check is simple: reduce the frequency step, and a real peak stays put while an aliased one moves.
How to measure
- Calibrate the analyser at the end of your test lead, not at the instrument socket. Otherwise the lead is added to every distance.
- Adapters between the lead and the feedline have length too, and a different vf. Centimetres, but noticeable on a short cable.
- Leave the far end open: then the end of the cable gives a strong reflection to measure from. If you terminate it in 50 Ω, the end disappears and only the faults remain.
- Measure a piece of known length first. If the instrument shows 10 m where there are 10, the setup is right.
What it will not show
- Distant faults behind a near one. The strong reflection from the first fault takes the signal, and what lies beyond is harder to see.
- Losses. In a long cable at high frequencies the reflection from the far end comes back weak, and small faults there drown in the noise.
- Exactly where the water is. Water spreads along the braid and gives not a point but a stretch. TDR shows where it starts; after that the cable is usually replaced.
The distance-to-fault calculator works out the distance from the resonance spacing, the delay or the phase.