Skip to main content

2 posts tagged with "feedline"

View all tags

Finding a Cable Fault with NanoVNA: Distance to Fault (TDR)

· 6 min read
UR3PKI
Software Engineer

You cannot cut a cable under the roof or in a conduit in half to see where it is damaged. But any damage reflects part of the signal, and the reflection comes back with a delay proportional to the distance. A NanoVNA can measure that delay — a fifty-dollar instrument many people already have in the shack. Below are two ways to do it, what limits range and accuracy, and how to read the picture.

The distance-to-fault calculator works out the distance from the measured numbers.

Ferrite Mix 31, 43, 52 or 61 for a Common-Mode Choke

· 6 min read
UR3PKI
Software Engineer

A common-mode choke on the feedline — a few turns of cable on a ferrite ring — is fitted to stop current flowing on the outside of the braid. The choke itself, and what my balun measurement did not prove, are covered in the post A 1:1 Dipole Balun on the NanoVNA. Here is the next question: which ferrite to wind it on.

The most common advice is "use 43". It is not bad advice, but it is not universal either: on the lower HF bands 43 loses noticeably to 31, and as a choke on HF 61 hardly works at all. You can see this from two numbers the manufacturer gives for every mix — μ′ and μ″.