Ferrite Mix 31, 43, 52 or 61 for a Common-Mode Choke
A common-mode choke on the feedline — a few turns of cable on a ferrite ring — is fitted to stop current flowing on the outside of the braid. The choke itself, and what my balun measurement did not prove, are covered in the post A 1:1 Dipole Balun on the NanoVNA. Here is the next question: which ferrite to wind it on.
The most common advice is "use 43". It is not bad advice, but it is not universal either: on the lower HF bands 43 loses noticeably to 31, and as a choke on HF 61 hardly works at all. You can see this from two numbers the manufacturer gives for every mix — μ′ and μ″.
The two parts of permeability
At radio frequencies the permeability of a ferrite is a complex number:
μ = μ′ − j·μ″
- μ′ is responsible for inductance: the bigger it is, the bigger the reactive part X;
- μ″ is responsible for loss: the bigger it is, the bigger the resistive part R.
The impedance of a winding of N turns on a ring:
Z = jω · N² · μ₀ · (μ′ − jμ″) · Ae / le
R = ω · N² · μ₀ · μ″ · Ae / le
X = ω · N² · μ₀ · μ′ · Ae / le
Ae is the cross-section of the ring and le the mean magnetic path length. Both are set by the size of the ring, while μ′ and μ″ are set by the mix and the frequency.
Why a choke needs μ″
A choke must block common-mode current. There are two ways to do it: a large reactance or a large resistance.
A reactive choke, together with the capacitance between its turns, forms a tuned circuit. At resonance its impedance is huge; a little way off resonance it is much lower. Its reactance also adds to the reactance of the rest of the path the common-mode current takes: the braid, the mast, the ground. With bad luck the choke does not suppress the current but merely shifts the resonance of that path.
A resistive choke simply absorbs the common-mode current in the ferrite as heat. Its impedance changes smoothly with frequency, it forms no sharp resonances, and it works the same whatever the reactance of the rest of the path. So a good choke for HF is one whose R is at least as large as X at the operating frequency, that is, μ″ at least as large as μ′.
What the Fair-Rite data say
Permeability of the mixes according to Fair-Rite, μ′ / μ″:
| Frequency | 31 | 43 | 52 | 61 |
|---|---|---|---|---|
| 1.8 MHz | 1045 / 693 | 911 / 177 | 267 / 4 | 124 / 1 |
| 3.6 MHz | 584 / 654 | 688 / 423 | 277 / 10 | 124 / 1 |
| 7 MHz | 336 / 452 | 399 / 396 | 299 / 66 | 126 / 1 |
| 14 MHz | 212 / 305 | 227 / 293 | 190 / 148 | 134 / 3 |
| 21 MHz | 157 / 249 | 163 / 241 | 132 / 128 | 152 / 16 |
| 28 MHz | 122 / 216 | 126 / 210 | 108 / 109 | 159 / 57 |
| 50 MHz | 65 / 155 | 66 / 152 | 79 / 85 | 80 / 83 |
| 145 MHz | 11 / 77 | 10 / 67 | 31 / 60 | 27 / 50 |
What this shows:
- 31 has the highest μ″ on 160, 80 and 40 m, and above 7 MHz its μ″ is no lower than that of 43. It is lossy from 1.8 MHz up.
- 43 is almost purely reactive on 160 m: its μ″ is four times lower than that of 31. From 7 MHz up, 43 and 31 are nearly identical. That is why "use 43" works on the upper HF bands and lets you down on the lower ones.
- 52 only gains loss from 14 MHz up, and its μ″ is half that of 31 or 43.
- 61 is almost lossless up to 14 MHz: it is a mix for high-Q coils and transformers, not for chokes. It only becomes lossy at 50 MHz and above.
Example: 10 turns on an FT-240
Let us work out a choke often fitted to a dipole feedline: 10 turns on an FT-240 ring (61 mm outside diameter). Ignoring the capacitance between turns:
| Band | 31: R / X | 43: R / X | 61: R / X |
|---|---|---|---|
| 160 m | 1117 / 1612 Ω | 293 / 1416 Ω | 1 / 192 Ω |
| 80 m | 1979 / 1766 Ω | 1280 / 2079 Ω | 2 / 375 Ω |
| 40 m | 2672 / 1982 Ω | 2353 / 2353 Ω | 6 / 751 Ω |
| 20 m | 3616 / 2503 Ω | 3472 / 2675 Ω | 38 / 1601 Ω |
| 10 m | 5128 / 2863 Ω | 4979 / 2955 Ω | 1437 / 3763 Ω |
On 160 m the resistive part of the choke on 31 is almost four times that on 43, and the total impedance a third higher. On 20 and 10 m there is practically no difference. On 61 the same choke on the lower bands is an ordinary inductor that absorbs nothing.
The choke calculator rates the total impedance |Z| like this: from 2000 Ω good, 1000–2000 acceptable, below 1000 too little. By that measure 10 turns on 160 m are "acceptable" on both mixes: 1960 Ω on an FT240-31 and 1450 Ω on an FT240-43. But of those 1450 Ω only 293 are resistive; the rest is reactance.
What the table does not show
The formula ignores the capacitance between turns. In reality it forms a resonance with the inductance, above which the choke impedance falls and turns from inductive to capacitive. The more turns, the lower the resonance. So you cannot keep raising the impedance by adding turns: somewhere in the middle of HF the resonance eats the gain.
A finished choke is checked by measurement: a NanoVNA across the two ends of the braid shows R, X and the resonance. How to measure properly, and what a straightforward measurement does not prove, is in the post on the balun.
In short
- 160 and 80 m — 31. On 43 you will need more turns, and the choke will still be mostly reactive.
- 40–10 m — 31 or 43, there is hardly any difference. Use whichever you have.
- 6 m and 2 m — few turns, several or even one, and what decides is no longer the mix but the capacitance between turns. According to the Fair-Rite data, 31 and 43 are no worse than 61 here.
- 61 and 52 on HF — for coils and transformers, not for chokes.
How many turns on which ring give the kilohms you need on your bands is worked out by the common-mode choke calculator.